Step | | Procedure & Parts & Tools |
1 |
|
REMOVE THE 6 SCREWS FROM THE HANDLE.
Screwdriver-phillips |
|
|
2 |
|
PULL THE COVER/CONTROL PANEL FROM THE MACHINE. TURN THE KEY ON AND ACTIVATE THE BRUSHES.
|
3 |
|
LOCATE BRUSH MOTOR PLUG ON THE CONTROL BOARD. INSERT THE VOLT METER LEADS INTO THE PLUG. VOLT METER SHOULD READ 24 VOLTS. IF BRUSH MOTOR IS OKAY, REASSEMBLE THE MACHINE.
Volt meter (True RMS capable) |
|
|
|